SEM images support the transformation process from porous glass granules to boron-containing CF-2 zeolite in morphology.
SEM照片从形貌上直观地表徵了多孔玻璃向CF-2沸石的转变过程。
This section describes the maintenance procedures for the CF-2 Fraction Collector These procedures can be performed by any person with proficiency in instrument maintenance or by an electronic technician.
本节阐述CF-2馏分收集器的维护程序。精通仪器维护的任何人或电气技术员能够实施这些程序。
The CF-2 Fraction Collector uses a 2 line, 40 character per line, supertwist liquid crystal display module.
CF-2馏分收集器采用双行,每行40个字符的超扭液晶显示模块。
The CF-2 fraction collector can operate with detectors having a 1V, 100 mV, or 10 mV full-scale output voltage.
CF-2馏分收集器能够与具有1V、100 mV或10 mV全刻度输出电压的传感器一起使用。
The analog input is used for the peak detection features of the CF-2 Fraction Collector.
CF-2馏分收集器的波峰检测功能采用模拟输入。
Also, if the peak separator is to be used, the UV Monitor's output must be connected to the CF-2 Fraction Collector's signal input.
此外,如果使用波峰分离器,紫外监测器的输出必须与CF-2馏分收集器的信号输入相连。
The Four Column Adapter (Part No. 124876) is an accessory for the CF-2 Fraction Collector which provides for the simultaneous collection of fractions from up to four columns.
四柱适配器(零件编号124876)是CF-2馏分收集器的一个配件,用于同时收集来自四根柱子的馏分物。
The CF-2 Fraction Collector uses a CMOS version of the venerable 8031 microprocessor operating at 11.0592 MHz.
CF-2馏分收集器采用以11.0592 MHz频率运行的CMOS型智能8031微处理器。外部锁存器用于构建16 bit地址总线。
The CF-2 Fraction Collector can work with a Spectra/Chrom MP-1 or MP-2 Pump (see Page 45 for ordering information) to provide volumetric collection, to stop the pump between tubes, or to stop the pump at the end of a run.
CF-2馏分收集器能够与Spectra/Chrom MP-1或MP-2泵(订购信息见第45页)一起使用,以根据容积收集液滴,停止试管间的泵,或在运行结束时停止泵。
CF-2 Fraction Collector Technical Specifications
CF-2馏分收集器技术规格:
124874 Mast package for CF-2 Fraction Collector. Attaches 2 vertical masts to the back of the fraction collector for supporting other laboratory items.
124874 CF-2馏分收集器桅杆包装。馏分收集器的背面放置支持其他实验室项目的2个垂直支架。
The Spectra/Chrom CF-2 Fraction Collector contains an internal nickel-cadmium battery which provides power to allow the Fraction Collector to retain information while it is unplugged.
Spectra/Chrom CF-2馏分收集器设有内置镍镉蓄电池,用于提供在馏分收集器与电源插座断开时允许馏分收集器保存信息所需的电力。
Prolonged exposure to X- or Gamma-rays may erase the EPROM in which the CF-2 program is stored.
长期接触X或γ射线可能会抹除保存在CF-2程序中的EPROM。