Examples with "to setting initial control values" and their translation in Japans
We konden deze vermelding niet vinden. Er worden benaderende resultaten weergegeven. Controleer je spelling of stel voor deze term aan het woordenboek toe te voegen.
An advantage to setting initial control values in the Initialize event is that the initialization code stays with the form.
この方法で初期値を設定すると、初期化コードがフォームに残ります。
An advantage to setting initial control values in the Initialize event is that the initialization code stays with the form.
You can also use code in the Initialize event of a form to set initial values for controls on the form. An advantage to setting initial control values in the Initialize event is that the initialization code stays with the form. You can copy the form to another project, and when you run the Show method to display the dialog box, the controls will be initialized.
The electric power steering apparatus comprises power self-holding means capable of controlling power off after the power is turned on by the IG switch, temperature estimating means for estimating the temperature of the heating part and controlling the temperature according to the estimated temperature, temperature estimating state storage means for storing predetermined data representing the state of the temperature estimation processing before the temperature estimating means stops in a storage section in a control unit, and initial value setting means for setting the initial value of the temperature estimated value according to the predetermined data when the IG switch is turned on again and the temperature estimating means operates.
A traction control device comprises a control commencement determination means (82), which determines whether to control a braking mechanism, and a traction force estimation unit (844), which estimates a traction force between a wheel and a road surface, wherein the traction force estimation unit (844) further comprises a control state determination unit (844A), which determines a control state of the braking mechanism based on a result of a determination by the control commencement determination means (82), a traction force initial value setting unit (844B), which sets an initial value according to a result of a determination by the control state determination unit (844A), and a traction force correction unit (844C), which corrects the traction force based on a control declination.
An encoding controller comprises offset holding means for holding an offset corresponding to the time by which the sound signal is to be encoded earlier than the video signal during chapter recording, recording mode judging means for judging whether or not seamless connection between a chapter and its succeeding chapter is possible and for setting an initial value of the offset according to the judgment result, offset updating means for updating the offset according to the progress of the encoding of the video signal and sound signal, and recording control means for issuing an instruction to start or stop the encoding of the video signal and sound signal according to the offset.
Therefore, this equalization signal processing device has: an equalization filter means for inputting a coherently received digital signal; a coefficient control means for controlling the coefficients that specify the characteristics of the equalization filter means; a significant coefficient holding means for holding a significant coefficient which is a significant value from among the initial values of the coefficients; a significant coefficient position determining means for determining a significant coefficient position which is a position in the initial value of the significant coefficient, in such a way as to optimize the equalization characteristics of the equalization filter means; and a significant coefficient setting means for setting the significant coefficient at the significant coefficient position.
The cranking torque control device is provided with: a setting means (22) that can set the output limit value, which is the limit value for power output from the battery, in accordance with power deviation when the motor is cranking the engine; and a control means (22) that controls the setting means in a manner so as not to set the output limit value under the condition that the battery voltage has fallen below a lower limit voltage of the battery as a result of the initial explosion of the engine or as a result of the oscillation of the engine.
The automatic gain control device includes a variable gain amplifier (101) for amplifying a reception signal by the set gain, a current position acquisition section for acquiring the current position of the local station upon communication start, a reception power prediction circuit (105) for calculating a communication distance between the local station and a communication partner station and predicting a reception level of the reception signal according to the calculated communication distance upon communication start, and an initial value setting circuit (104) for setting the gain initial value according to the reception level of the reception signal predicted.
The reason why this method is better compared to the method introduced in the previous Section 1.5.3 (where each program has its own ENTRY statement for setting imiss) is because the information held by glpget can be inquired from multiple subroutines. For example, the initial value of all missing values is given as 999, but in the case where 999 falls within the range of possible data, this value must be changed. With this method, the glpset only has to be called once to control the operation of all subroutines that handles missing values.
When a disk group is created, ASM creates a set of default templates for that disk group. The set consists of one template for each file type (data file, control file, redo log file, and so on) supported by ASM. Default template settings depend on the disk group type. For example, the default template for datafiles for a normal redundancy disk group sets 2-way mirroring, while the corresponding default template in a high redundancy disk group sets 3-way mirroring. The table below lists the default templates and the attributes that they apply to matching files. As the table shows, the initial redundancy value of each default template depends on the type of disk group that the template belongs to.
It does this by reading the initial values of the bones and setting the Control Offset Transform, placing the controls in the appropriate locations for the skeleton.
Er worden alleen voorbeelden gegeven om u te helpen het woord of de woordcombinatie waarop u hebt gezocht, te vertalen. Deze worden niet door ons geselecteerd of gevalideerd en kunnen ongepaste taal bevatten. Wij vragen u melding te maken van voorbeelden die dienen te worden aangepast of verwijderd. Vertalingen met grof of informeel taalgebruik worden meestal rood of oranje gemarkeerd.