Traduction de "input data latch circuit" en chinois
Nous n’avons pas trouvé cette entrée. Affichage de résultats approximatifs. Vérifiez l’orthographe ou proposez d’ajouter ce terme au dictionnaire.
输入数据锁存电路
The input data control unit 42 has a write clock buffer WCLKB, an input data latch circuit IDLT, and a write data bus switch WDBSW. FIG. 7 illustrates the input data control unit 42 corresponding to one data terminal DQ (DINZ). The write clock buffer WCLKB generates a write clock signal WCLKZ in synchronization with the clock signal CLKZ when the write signal WRZ is activated at the high level. For example, the write clock signal WCLKZ is activated the number of clock cycles corresponding to a burst length.
The NAND gate and the NOR gate invert the logic of the input data signal DINZ supplied via the input data latch circuit IDLT and output it to the pMOS transistor P6 and the nMOS transistor N6 respectively. If the input data signal DINZ is at the high level, the pMOS transistor P6 is turned on and the nMOS transistor N6 is turned off, to set a common data line CDBZ to the high level. If the input data signal DINZ is at the low level, the pMOS transistor P6 is turned off and the nMOS transistor N6 is turned on, to set the common data line CDBZ to the low level. When supplied with the low-level (inactive) write signal WRZ, the write data bus switch WDBSW turns off the pMOS transistor P6 and the nMOS transistor N6 in order to set the common data line CDBZ into the floating state. In order to do so, the first power supply voltage VIIR is supplied to the write data bus switch WDBSW.
The input data latch circuit IDLT is the same as the command latch circuit CLAT. The input data latch circuit IDLT receives the input data signal DINZ in the low-level period of the write clock signal WCLKZ, to and latch the input data DINZ in synchronization with the leading edge of the write clock signal WCLKZ and output it to the write data bus switch WDBSW.
If the delay time tDLY is long such that the switch 32 may be turned on after the write command WR or the read command RD is accepted by the command control unit 16, a deficiency may occur in capacity of supplying power to the column control unit 36, the output data control unit 40, and the input data control unit 42 ((f) of FIG. 10). In this case, the internal power supply voltage VIIC drops. Moreover, after the switch 32 is turned on, the internal power supply voltage VIIR drops due to charge sharing. A drop in internal power supply voltage VIIR may affect the operations of the column control unit 36, the output data control unit 40, and the input data control unit 42. For example, the timing at which the input data latch circuit IDLT in the input data control unit 42 illustrated in FIG. 7 latches the input data signal DINZ may possibly shift. Therefore, it is desirable that the switch 32 may be turned on before the column control unit 36, the output data control unit 40, and the input data control unit 42 start to operate, that is, before the write command WR or the read command RD is accepted.
The write clock buffer WCLKB and the input data latch circuit IDLT operate in a period when the internal power supply voltage VIIC is generated when the pMOS transistor P3 illustrated in FIG. 4 is turned on. The write clock buffer WCLKB and the input data latch circuit IDLT stop operating in a period when the internal power supply voltage VIIC is not generated when the pMOS transistor P3 is turned off. The write data bus switch WDBSW operates as it receives the internal power supply voltage VIIR generated in a period except in the deep power-down mode. The pMOS transistor P6 and the nMOS transistor N6 are turned off by the low-level (inactive) write signal WRZ. Accordingly, it is possible to prevent the write data bus switch WDBSW from malfunctioning when the write clock buffer WCLKB and the input data latch circuit IDLT are stopped in operation.
As hereinabove described, the present embodiment provides almost the same effects as those by the earlier described embodiments. Moreover, the switch 32 is turned on after the internal power supply voltage VIIC rises to the first voltage V1 and before the column control unit 36, the output data control unit 40, and the input data control unit 42 start to operate. It is thus possible to prevent fluctuations in internal power supply voltage VIIC, thereby preventing a shift in timing at which the row control unit 34 activates the word line signal WLZ and the sense-amplifier control signal SAEZ. Further, when the switch 32 is turned on, the internal power supply voltage VIIR is supplied to the internal power supply line VIIC, thereby enabling stabilizing the internal power supply voltage VIIC. It is thus possible to prevent a shift in timing at which the input data latch circuit IDLT in the input data control unit 42 latches the input data signal DINZ. That is, it is possible to prevent operations of the column control unit 36, the output data control unit 40, and the input data control unit 42 from being affected.
Les exemples vous aident à traduire le mot ou l’expression cherchés dans des contextes variés. Ils ne sont ni sélectionnés ni validés par nous et peuvent contenir des mots ou des idées inappropriés. Signalez des exemples à modifier ou à retirer. Les traductions potentiellement sensibles, inappropriées ou familières sont généralement marquées de rouge ou d’orange.